All Available Sizes:
| Lbs./SF |
Actual Thickness |
Maximum Size |
Lbs./SF |
Actual Thickness |
Maximum Size |
| Common, Chemical or Antimonial Lead |
(inches) |
(feet) |
Common, Chemical or Antimonial Lead |
(inches) |
(feet) |
| |
Decimal |
Fraction |
Width |
Length |
|
Decimal |
Fraction |
Width |
length |
| 1.0 |
0.016 |
1/64 |
4 |
25 |
|
|
|
|
|
| 2.0 |
0.033 |
1/32 |
8 |
25 |
22.5 |
0.375 |
8/8 |
8 |
|
| 2.5 |
0.041 |
1/24 |
8 |
25 |
|
|
|
|
|
| 3.0 |
0.05 |
- |
8 |
25 |
|
|
|
|
|
| 3.5 |
0.058 |
- |
8 |
25 |
24 |
0.4 |
2/5 |
8 |
20 |
| 3.75 |
0.063 |
1/16 |
8 |
25 |
|
|
|
|
|
| 4.0 |
0.066 |
- |
8 |
25 |
|
|
|
|
|
| 5.0 |
0.082 |
1/12 |
8 |
25 |
30 |
0.5 |
1/2 |
0.8 |
20 |
| 6.0 |
0.1 |
1/10 |
8 |
25 |
|
|
|
|
|
| 6.5 |
0.105 |
- |
8 |
25 |
|
|
|
|
|
| 7.0 |
0.117 |
- |
8 |
25 |
40 |
0.667 |
2/3 |
8 |
20 |
| 7.5 |
0.125 |
1/8 |
8 |
25 |
|
|
|
|
|
| 8.0 |
0.133 |
- |
8 |
25 |
|
|
|
|
|
| 10 |
0.167 |
1/6 |
8 |
20 |
45 |
0.75 |
3/4 |
8 |
20 |
| 11.25 |
0.187 |
3/16 |
8 |
20 |
|
|
|
|
|
| 12 |
0.2 |
1/5 |
8 |
20 |
|
|
|
|
|
| 15 |
0.25 |
1/4 |
8 |
20 |
|
|
|
|
|
| 16 |
0.267 |
- |
8 |
20 |
60 |
1 |
1 |
8 |
20 |
| 20 |
0.333 |
1/3 |
8 |
20 |
|
|
|
|
|
Stock Sheet Lead Sizes:
2, 4, & 8 LB. are sold in Rolls, 16 LB. in full sheets. Stock Sheet Sizes are 48" wide x 120" long (40 Square feet per sheet) and 48" wide x 96" long (32 Square feet per sheet). Custom cut sizes may be available, call us for more information.
Note: MarShield™ Sheet Lead is true weight and thickness.
Recommended Lead Sheet Thickness' for Gamma Shielding:
| Energy (mev) |
| Activity |
0.2 |
0.5 |
0.8 |
1 |
1.5 |
2 |
2.5 |
3 |
4 |
| 10 mc |
-0.14 |
-0.36 |
-0.27 |
-0.11 |
0.37 |
0.78 |
1.15 |
1.4 |
1.7 |
| 20 mc |
-0.09 |
0 |
0.41 |
0.076 |
1.57 |
2.16 |
2.63 |
2.91 |
3.21 |
| 50 mc |
-0.01 |
0.47 |
1.13 |
1.9 |
3.15 |
4 |
4.57 |
4.9 |
5.2 |
| 100 mc |
0.06 |
0.82 |
1.99 |
2.77 |
4.34 |
5.38 |
6.05 |
6.41 |
6.71 |
| 200 mc |
0.1 |
1.17 |
2.67 |
3.63 |
5.54 |
6.77 |
7.52 |
7.92 |
8.21 |
| 500 mc |
0.17 |
1.94 |
3.57 |
4.78 |
7.12 |
8.6 |
9.47 |
9.91 |
10.21 |
| 1 c |
0.23 |
1.99 |
4.25 |
5.56 |
8.31 |
9.99 |
10.95 |
11.41 |
11.74 |
| 2 c |
0.28 |
2.35 |
4.93 |
6.52 |
9.51 |
11.37 |
12.42 |
12.92 |
13.72 |
| 5 c |
0.36 |
2.81 |
5.82 |
7.85 |
11.09 |
13.21 |
14.37 |
14.91 |
15.21 |
| 10 c |
0.41 |
3.17 |
6.5 |
8.52 |
12.28 |
14.58 |
15.85 |
16.42 |
16.72 |
| 20 c |
0.47 |
3.52 |
7.18 |
9.39 |
13.48 |
15.98 |
17.23 |
17.93 |
18.23 |
| 50 c |
0.54 |
3.99 |
8.08 |
10.54 |
16.06 |
17.81 |
19.27 |
19.92 |
20.22 |
| 100 c |
0.6 |
4.34 |
8.78 |
11.4 |
16.25 |
19.2 |
20.75 |
21.43 |
21.72 |
| Danger Range |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
| 20 cm |
0.26 |
1.64 |
3.15 |
4.02 |
5.55 |
6.44 |
6.85 |
7.0 |
7.0 |
| 50 cm |
0.11 |
0.71 |
1.36 |
1.73 |
2.39 |
2.77 |
2.95 |
3.01 |
3.01 |
| 1 m |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
| 2 m |
-0.11 |
-0.71 |
-1.36 |
-1.72 |
-2.39 |
-2.77 |
-2.95 |
-3.01 |
-3.01 |
| 5 m |
-0.26 |
-1.64 |
-3.15 |
-4.02 |
-5.55 |
-6.44 |
-6.85 |
-7.0 |
-7.0 |
| 10 m |
-0.037 |
-2.35 |
-4.52 |
-5.76 |
-7.94 |
-9.21 |
-9.8 |
-10.01 |
-10.01 |
| Working time hr/day |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
Plus |
| 1 |
-0.17 |
-1.06 |
-2.04 |
-2.6 |
-3.59 |
-4.16 |
-4.42 |
-4.52 |
| 2 |
-0.11 |
-0.71 |
-1.36 |
-1.73 |
-2.39 |
-2.77 |
-2.95 |
-3.01 |
| 4 |
-0.06 |
-0.35 |
-0.65 |
-0.87 |
-1.2 |
-1.39 |
-1.47 |
-1.51 |
| 8 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
| 24 |
0.09 |
0.56 |
1.06 |
1.37 |
1.89 |
2.2 |
2.34 |
2.39 |
Recommended Lead Sheet Thickness' for X-Ray Rooms:
| X-Rays Generated by Peak Voltages Not Exceeding |
Minimum Thickness of Lead |
Weight per Square Foot in Pounds |
| Millimetre |
Inches |
| 75 kv |
1.0 |
0.039 |
2 1/2 |
| 100 kv |
1.5 |
0.059 |
4 |
| 125 kv |
2.0 |
0.079 |
5 |
| 150 kv |
2.5 |
0.093 |
7 |
| 175 kv |
3.0 |
0.118 |
8 |
| 200 kv |
4.0 |
0.157 |
10 |
| 225 kv |
2.0 |
0.197 |
13 |
| 300 kv |
9.0 |
0.354 |
24 |
| 400 kv |
15.0 |
0.591 |
38 |
| 600 kv |
34.0 |
1.343 |
81 |
| 900 kv |
51.0 |
2.0 |
120 |